For security purposes
FOR SECURITY PURPOSES - because Internet Explorer is no longer supported by Microsoft, we suggest that you interact with our secure site through one of our supported browsers - Google Chrome, Firefox, or MS Edge. If you continue to use this website with Internet Explorer you do so at your own risk and you may encounter problems.
Product Information
Phase Detail
Zebron ZB-5MSi GC Columns
Zebron ZB-5MSi GC columns offer improved peak shape of acidic/basic compounds, drugs of abuse, and pesticides

Zebron ZB-5MSi GC Columns

Inert, Low Bleed 5% Phenyl Selectivity

  • Highly inert for improved peak shape of acidic/basic compounds, drugs of abuse, and pesticides
  • MS certified low bleed levels provide maximum sensitivity
  • Industry leading QC specifications ensure column-to-column performance
  • Traditional bonding chemistry provides the same selectivity as other 5% phenyl columns
Running semi-volatiles, PAHs, or PBDEs? SeeZB-SEMIVOLATILES
Testing for drugs of abuse? See ZB-Drug-1

Recommended Use
Drugs, EPA Methods, FAMEs, Nitrosamines, Pesticides, Phenols

Upgrade to Zebron from any
5 % phenyl / 95 % dimethylpolysiloxane phase:

Agilent® Restek® SGE® Supelco® OV®
DB®-5
HP-5
HP-5ms
HP-5msi
Rtx®-5
Rtx-5MS
Rtx-5Amine
Rxi-5ms
BP5
BPX5
MDN-5
SPB®-5
Equity®-5
OV-5

General Selection Guidelines

The following selection guidelines are for choosing a Zebron™ 5 phase column. Please contact your Phenomenex representative for additional assistance.

General Selection Guidelines


5 % Phenyl Phases

  • Versatile for a wide analyte range
  • Available in standard, inert, and high temperature styles
  • Replace 5% phenyl 95% dimethylpolysiloxane phases from Agilent®, Restek®, Supelco®, and other manufacturers

Endocrine Disruptors by GC/MS

Column:
Zebron ZB-5MSi
Dimension:
30 meter x 0.25 mm x 0.25  µm
Part No.:
7HG-G018-11
Injection Volume:
Split 40:1 @ 250 °C, 1 µL
Carrier Gas:
Helium @ 1.2 mL/min (constant flow)
Oven Program:
100 °C to 180 °C @ 5 °C/min to 320 °C @ 5 °C/min
Detector:
MSD @ 180 °C, 45-450 amu
Sample:
Analytes are 50 ppm in acetone
1. Dimethyl phthalate
2. Diethyl phthalate
3. Atraton
4. Simazine
5. Prometon
6. Atrazine
7. Propazine
8. Dipropyl phthalate
9. Terbuthylazine
10. Secbumetone
11. Simetryn
12. Ametryn
13. Prometryn
14. Terbutryn
15. Dibutyl phthalate
16. 4,4’-DDE
17. 4,4’-DDD
18. Di-n-hexyl phthalate
19. 4,4’-DDT
20. Dicyclohexyl phthalate
21. bis(2-Ethylhexyl)phthalate
22. Di-n-octyl phthalate
23. Ethinyl estradiol