Recommended Use Optimized, versatile selectivity for chlorinated pesticides, herbicides, and PCBs by GC-ECD |
Restek® | |
---|---|
Rtx®-CLPesticides Rtx-CLPesticides2 |
Stx®-CLPesticides Stx-CLPesticides2 |
*Direct replacement: this category indicates an alternative column which will likely give a similar selectivity.
You asked for optimized performance for pesticides by GC/ECD detectors, without time-consuming method development. We’ve delivered a direct replacement*! ZB-CLPesticides-1 and -2 provide guaranteed drop-in performance compared to your current Rtx-CLPesticides column set, without the hassle.
“ I was able to install the ZB-CLPesticides-1 and ZB-CLPesticides-2 columns as a direct replacement for the Restek Rtx-CLPesticides and Rtx-CLPesticides2 columns that I currently use. I made no changes to the method and saw very little difference between the two columns.“
Joanne Foy, Chemist
TriMatrix Laboratories, Inc.
The opinions stated herein are solely those of the speaker and not necessarily those of any company or organization.
ZB-CLPesticides columns combine Zebron high quality with drop-in selectivity. Achieve near-exact elution profiles and run times, without the time-consuming method development and headaches typical of traditional selectivities!
Zebron
Restek®
Column:
As listed
|
|
Dimension:
As listed
|
|
Part No.:
7HM-G028-51 (ZB-CLPesticides-1)
7HM-G029-11 (ZB-CLPesticides-2) |
|
Injection:
Splitless (hold 0.3 min) @ 250 °C, 1 µL
|
|
Carrier Gas:
Helium @ 3.9 mL/min (constant flow)
|
Oven Program:
120 °C to 200 °C @ 45 °C/min to 230 °C @ 15 °C/min to 330 °C @ 30 °C/min for 2 min
|
|
Detector:
ECD @ 330 °C |
|
Y-Connector:
AG0-4717 (Fused Quartz) |
|
Guard Column:
7AM-G000-00-GZ0 (5 m Z-Guardâ„¢) |
|
Liner:
AG0-8499 (Single Taper with Wool at Bottom) |
|
Septum:
AG0-4696 (PhenoRedâ„¢-400) |
|
Inlet Seal:
AG0-8620 (Gold-Plated Easy Sealâ„¢) |
Sample:
Analytes are 250 ng/mL in hexane.1. 2,4,5,6-TCMX (Surr) 2. α-BHC 3. γ-BHC 4. β-BHC 5. δ-BHC 6. Heptachlor 7. Aldrin 8. Heptachlor epoxide 9. trans-Chlordane 10. cis-Chlordane 11. 4,4’-DDE 12. Endosulfan I 13. Dieldrin 14. Endrin 15. 4,4’-DDD 16. Endosulfan II 17. 4,4’-DDT 18. Endrin aldehyde 19. Endosulfan sulfate 20. Methoxychlor 21. Endrin ketone 22. Decachlorobiphenyl (Surr) |
Peak No.
|
Analyte
|
ZB-CLPesticides-1
% RSD* |
ZB-CLPesticides-2
% RSD* |
US EPA Specifications
|
---|---|---|---|---|
1
|
2,4,5,6-TCMX (Surr) | 3.8 |
3.0
|
< 20
|
2
|
α-BHC | 8.3 |
3.8
|
< 20
|
3
|
γ-BHC | 5.9 |
5.6
|
< 20
|
4
|
β-BHC | 6.9 |
6.9
|
< 20
|
5
|
δ-BHC | 4.9 |
5.7
|
< 20
|
6
|
Heptachlor | 8.0 |
6.5
|
< 20
|
7
|
Aldrin | 4.2 |
2.3
|
< 20
|
8
|
Heptachlor epoxide | 3.8 |
2.3
|
< 20
|
9
|
trans-Chlordane | 4.1 |
3.8
|
< 20
|
10
|
cis-Chlordane | 4.0 |
3.3
|
< 20
|
11
|
4,4'-DDE | 4.8 |
2.9
|
< 20
|
12
|
Endosulfan I | 6.0 |
2.5
|
< 20
|
13
|
Dieldrin | 7.7 |
4.9
|
< 20
|
14
|
Endrin | 9.4 |
6.6
|
< 20
|
15
|
4,4'-DDD | 9.2 |
3.6
|
< 20
|
16
|
Endosulfan II | 6.6 |
4.1
|
< 20
|
17
|
4,4'-DDT | 11.6 |
6.9
|
< 20
|
18
|
Endrin aldehyde | 8.3 |
7.3
|
< 20
|
19
|
Endosulfan sulfate | 8.0 |
7.1
|
< 20
|
20
|
Methoxychlor | 6.7 |
6.1
|
< 20
|
21
|
|
6.5 |
7.2
|
< 20
|
22
|
Decachlorobiphenyl (Surr) | 6.7 |
6.6
|
< 20
|
Average | 6.6% |
4.9%
|
< 20
|
*Calculated using response factors as per EPA guidelines
ZB-CLPesticides columns combine Zebron high quality with drop-in selectivity. Achieve near-exact elution profiles and run times, without the time-consuming method development and headaches typical of traditional selectivities!
Zebron
Restek®
Columns:
As listed
|
|
Dimension:
As listed
|
|
Part No.:
7HM-G028-51 (ZB-CLPesticides-1)
7HM-G029-11 (ZB-CLPesticides-2) |
|
Injection:
Pulsed Splitless @ 30 psi (hold 20 sec)
@ 250 °C, 1 µL |
Carrier Gas:
Helium @ 60 cm/sec (constant flow)
|
|
Oven Program:
120 °C to 200 °C @ 45 °C/min to 330 °C @ 15 °C/min for 2 min
|
|
Detector:
ECD @ 330 °C |
|
Y-Connector:
AG0-4717 (Fused Quartz) |
|
Guard Column:
7AM-G000-00-GZ0 (5 m Z-Guardâ„¢) |
Liner:
AG0-8499 (Single Taper with Wool at Bottom) |
|
Septum:
AG0-4696 (PhenoRedâ„¢-400) |
|
Inlet Seal:
AG0-8620 (Gold-Plated Easy Sealâ„¢) |
|
Sample:
Aroclor is 1000 ng/mL and SS and IS are 100 ng/mL in hexane. 1. Tetrachloro-meta-xylene (TCMX)* 2. Decachlorobiphenyl** |
* surrogate standard
** internal standard
Who Needs to Use Certified Reference Materials?
All environmental labs accredited to ISO/IEC 17025 must use CRMs. Even if your lab does not have this accreditation it still benefits from having a high standard, quality product.