For security purposes
FOR SECURITY PURPOSES - because Internet Explorer is no longer supported by Microsoft, we suggest that you interact with our secure site through one of our supported browsers - Google Chrome, Firefox, or MS Edge. If you continue to use this website with Internet Explorer you do so at your own risk and you may encounter problems.
Product Information
Phase Detail
Zebron ZB-35HT Inferno GC Columns<br class="t-last-br" />
Zebron ZB-35HT Inferno GC column is a non-metal, 35 % phenyl columns stable to 400 ˚C

Zebron ZB-35HT Inferno GC Columns

High Temperature Stability for Mid-Polarity

  • First non-metal, 35 % phenyl columns stable to 400 ˚C
  • Longer lifetime with rugged high temperature, polyimide coated, fused silica tubing
  • Robust column for high temperature analysis
  • Great for high molecular weight compounds
  • Eliminate carry-over with high temperature bake outs
  • Low activity, provides good peak shape for acidic and basic samples

Recommended Use
Amines, Aroclors, Chemicals, Drugs, EPA Methods (508, 608, 8081, 8141, 8151), Pesticides, Pharmaceuticals, Semi-volatiles, Steroids

R&D100 Logo 

R&D 100 Award-Winning
Technology for High Temp Testing with advanced polymer bonding technology and specialized high temperature polyimide coating, Zebron Inferno columns offer enhanced performance where other columns fail. See how Inferno columns allow analysts to push a standard analysis up to 430 °C. Download the brochure here.


Recommended Use
Intermediate polarity with high temperature stability (up to 400 °C) for high boilers, contaminants, carry-overs, and high-temp bakeouts

Upgrade to Zebron from any
35 % phenyl / 65 % dimethylpolysiloxane phase:

Agilent® Restek® SGE® Supelco® OV®

DB®-35
DB-35ms
HP-35

Rtx®-35
Rtx-35ms
BPX35
BPX608
MDN-35
SPB®-35
SPB-608
OV-11

Lower Bleed Than Other Columns!

Great Separation of High Boiling Hydrocarbons (ASTM D6352)

Conditions for all columns:

Dimension:
30 meter x 0.25 mm x 0.25 μm
Injection:
Split 20:1 @ 200 °C, 1 µL
Carrier Gas:
Helium @ 1.7 mL/min (constant flow)
Oven Program:
100 °C to 320 °C @ 30 °C/min for 5 min to
340 °C @ 20 °C/min for 5 min to 360 °C @
20 °C/min for 5 min to 380 °C @ 20 °C/min
for 5 min to 400 °C @ 20 °C/min for 5 min to 100 °C @ 30 °C/min for 8 min
Detector:
FID @ 405 °C

See What You’ve Been Missing

Conditions for all columns:

Part No.:
7HG-G025-11 (ZB-35HT Inferno)
Injection:
A) Split 50:1 @ 350 °C, 1 µL
B) Split 50:1 @ 300 °C, 1 µL
Carrier Gas:
Helium @ 2.1 mL/min (constant flow)
Oven Program:
A) 140 °C to 400 °C @ 10 °C/min
B) 140 °C to 300 °C @ 10 °C/min
Detector:
A) FID @ 400 °C
B) FID @ 320 °C
Sample:
1. Hexadecylamine
Note:
Chromatogram is courtesy of Northeastern Chemical Company.

Well-Suited for Environmental Contaminants

PAHs and PCBs In A Single Run

Column:
Zebron ZB-35 Inferno
Dimension:
30 meter x 0.25 mm x 0.25 µm
Part No.:
7HG-G025-11
Injection:
Splitless @ 265 °C, 2 µL
Carrier Gas:
Helium @ 1 mL/min (constant flow)
Oven Program:
85 °C for 3 min to 320 °C @ 7 °C /min
for 8 min
Detector:
MSD @ 280 °C

Sample:
Compounds are 5 ppm
1. Naphthalene
2. Acenaphthylene
3. Acenaphthene
4. Fluorene
5. Phenanthrene
6. Anthracene
7. PCB 28
8. PCB 52
9. PCB 101
10. Fluoranthene
11. Pyrene
Sample:
12. PCB 118
13. PCB 153
14. PCB 138
15. PCB 180
16. Benz[a]anthracene
17. Chrysene
18. PCB 194
19. Benzo[b]fluoranthene
20. Benzo[k]fluoranthene
21. Benzo[a]pyrene
22. Indeno[1,2,3-cd]pyrene
23. Dibenz[a,h]anthracene
24. Benzo[g,h,I]perylene