Fractionation of neutral compounds such as amides from acidic and basic analytes. Offers a strong cation exchange group and a weak anion exchange group for the extraction or fractionation of complex mixtures.
Surface Area (m²/g) m²/g |
Separation Mode Multi-Mode |
Particle Size 55 |
Recommended Use Fractionation of neutral compounds such as amides from acidic and basic analytes |
1, 3, and 6mL Tubes
Giga Tubes (12-150mL Tubes)
Improved design with a dual wall housing (Glass and Plastic). Glass prevents diffusion, ensuring a leak and contaminant free system (Glass and Plastic).
Condition:
1 mL Methanol |
|
Equilibrate
1 mL DI Water |
|
Load:
Pretreated sample, pH 6-7 |
|
Wash 1:
1 mL 25 mM Ammonium Acetate Buffer, pH 6-7 |
|
Wash 2:
1 mL Methanol, dry under vacuum for 2-5 min |
|
Elute:
1 mL 5% Formic Acid in Methanol |
Based on 100 mg/1 mL sorbent mass. The above is a convenient starting point for SPE
method development, further optimization may be required to tailor the method for your
specific extraction needs.