The immobilization and bonding technology used within the Lux i-Cellulose-5 promotes column stability in strong organic solvents, which affords you the ability to expand your chiral separation success with more solvent systems and separation modes.
Separation Mode Chiral |
Recommended Use Separation of enantiomers and racemic mixtures by reversed phase, normal phase, polar organic and SFC with a fully porous particle, immobilized with a polysaccharide stationary phase. This Immobilization provides additional strong organic solvent ruggedness so that DCM, DMSO and other related strong solvents can be used on column. |
Lux® i-Cellulose-5 contains achemical crosslinking between the polysaccharide and silica supports which inturn provides incredible strong solvent (THF, DCM, DMSO, MtBE, Ethyl Acetate, etc.) robustness compared to coated phases and prevents the phase from being dissolved in strong solvents.
Lower pressure, all purpose particle size for analytical LC (HPLC) or SFC methods and especially for high performance preparative LC or SFC purification work.
Dimension:
250 x 4.6 mm |
Mobile Phase:
0.1 % Ethylamine in DCM / 0.1 % Ethylamine in Methanol (98:2) |
Flow Rate:
1 mL/min |
Temperature:
Ambient |
Detection:
UV @ 270 nm |
Sample:
Althiazide |
Dimension:
250 x 4.6 mm |
Mobile Phase:
0.1 % Ethylamine in MtBE / 0.1 % Ethylamine in Methanol (96:4) |
Flow Rate:
1 mL/min |
Temperature:
Ambient |
Detection:
UV @ 254 nm |
Sample:
Chlorthalidone |
Dimension:
250 x 4.6 mm |
Mobile Phase:
0.1 % Ethylamine in MtBE |
Flow Rate:
1 mL/min |
Temperature:
Ambient |
Detection:
UV @ 254 nm |
Sample:
Ornidazole |
Dimension:
250 x 4.6 mm
|
Part No.:
00G-4756-E0
|
Mobile Phase:
5 mM Ammonium Bicarbonate/
Acetonitrile (20:80) |
Flow Rate:
1 mL/min
|
Temperature:
20 ˚C |
Detection:
UV @ 254 nmMS (Advion® Single Quad) |
Dimension:
250 x 4.6 mm |
Part No.:
00G-4756-E0 |
Mobile Phase:
n-Hexane/Ethanol/DEA (80:20:0.1) |
Flow Rate:
1.5 mL/min |
Temperature:
27 ˚C |
Detection:
UV @ 230 nm |
Dimension:
250 x 4.6 mm |
Part No.:
00G-4756-E0 |
Mobile Phase:
n-Hexane/Isopropanol (80:20) |
Flow Rate:
1.5 mL/min |
Temperature:
20 ˚C |
Detection:
UV @ 210 nm |
Dimension:
250 x 4.6 mm
|
Part No.:
00G-4756-E0
|
Mobile Phase:
100% DCM (CH2CI2)
|
Flow Rate:
1.0 mL/min
|
Temperature:
25 ˚C |
Detection:
UV @ 254 nm |
Dimension:
250 x 4.6 mm |
Part No.:
00G-4756-E0 |
Mobile Phase:
100% THF |
Flow Rate:
1.0 mL/min |
Temperature:
25 ˚C |
Detection:
UV @ 210 nm |
If you are using one of the DAICEL columns below: | Guaranteed alternative: |
Phase description: |
---|---|---|
CHIRALPAK® IA® | Lux i-Amylose-1 | Amylose tris(3,5-dimethylphenylcarbamate) |
CHIRALPAK IG® and IG-3 | Lux i-Amylose-3 | Amylose tris(3-chloro-5-methylphenylcarbamate) |
CHIRALPAK IC® and IC-3 | Lux i-Cellulose-5 | Cellulose tris(3,5-dichlorophenylcarbamate) |
CHIRALPAK AD®, AD-H®, AD-3, AD-RH®, and AD-3R | Lux Amylose-1 | Amylose tris(3,5-dimethylphenylcarbamate) |
CHIRALPAK AY®, AY-H®, AY-3, AY-RH, and AY-3R | Lux Amylose-2 | Amylose tris(5-chloro-2-methylphenylcarbamate) |
CHIRALCEL® OD®, OD-H®, OD-3, OD-RH®, and OD-3R | Lux Cellulose-1 | Cellulose tris(3,5-dimethylphenylcarbamate) |
CHIRALCEL OZ, OZ-H®, OZ-3, OZ-RH, and OZ-3R | Lux Cellulose-2 | Cellulose tris(3-chloro-4-methylphenylcarbamate) |
CHIRALCEL OJ®, OJ-H®, OJ-3, OJ-RH®, and OJ-3R | Lux Cellulose-3 | Cellulose tris(4-methylbenzoate) |
CHIRALCEL OX-H, OX-3, OX-RH, and OX-3R | Lux Cellulose-4 | Cellulose tris(3-chloro-4-methylphenylcarbamate) |