The immobilization and bonding technology used within the Lux i-Amylose-3 promotes column stability in strong organic solvents, which affords you the ability to expand your chiral separation success with more solvent systems and separation modes.
The Lux i-Amylose-3, like the rest of the Lux product line, is an incredibly versatile phase that has been manufactured and developed to give you your desired results again and again. This is especially true under harsh conditions where coated phases are unable to perform.
Lower pressure, all purpose particle size for analytical LC (HPLC) or SFC methods and especially for high performance preparative LC or SFC purification work.
Column:
Lux 5 µm i-Amylose-3 Lux 3 µm i-Amylose-3 |
Dimension:
250 x 4.6 mm |
Mobile Phase:
Methanol with 0.05 % Formic Acid |
Flow Rate:
0.6 mL/min |
Injection Volume:
10 µL (2 mg/mL) |
Detection:
UV @ 220 nm |
Sample:
1. Carprofen2. Carprofen |
Column:
Lux 5 µm i-Amylose-3 CHIRALPAK IG |
Dimension:
250 x 4.6 mm |
Mobile Phase:
Methanol with 0.05 % Formic Acid |
Flow Rate:
0.6 mL/min |
Injection Volume:
10 µL (2 mg/mL) |
Detection:
UV @ 254 nm |
Sample:
1. Warfarin2. Warfarin |
Column:
Lux 5 µm i-Amylose-3
Lux 5 µm i-Cellulose-5 Lux 5 µm i-Amylose-1 |
Dimension:
250 x 4.6 mm
|
Part No.:
00G-4779-E0
00G-4756-E0 00G-4762-E0 |
Mobile Phase:
Water with 0.1 % Diethylamine/
Acetonitrile (35:65) |
Flow Rate:
1.0 mL/min
|
Injection Volume:
10 µL (2 mg/mL) |
Detection:
UV @ 254 nm |
Sample:
1. Diniconazole |
Column:
Lux 5 µm i-Amylose-3
Lux 5 µm i-Cellulose-5 Lux 5 µm i-Amylose-1 |
Dimension:
250 x 4.6 mm
|
Part No.:
00G-4779-E0
00G-4756-E0 00G-4762-E0 |
Mobile Phase:
Acetonitrile with 0.1 % Diethylamine
|
Flow Rate:
1.0 mL/min
|
Injection Volume:
10 µL (2 mg/mL) |
Detection:
UV @ 254 nm |
Sample:
1. Thalidomide |
Column:
Lux 5 µm i-Amylose-3
Lux 5 µm i-Cellulose-5 Lux 5 µm i-Amylose-1 |
Dimension:
250 x 4.6 mm
|
Part No.:
00G-4779-E0
00G-4756-E0 00G-4762-E0 |
Mobile Phase:
Acetonitrile with 0.1 % Formic Acid
|
Flow Rate:
1.0 mL/min
|
Injection Volume:
10 µL (2 mg/mL) |
Detection:
UV @ 254 nm |
Sample:
1. Indoprofen |
If you are using one of the DAICEL columns below: | Guaranteed alternative: |
Phase description: |
---|---|---|
CHIRALPAK® IA® | Lux i-Amylose-1 | Amylose tris(3,5-dimethylphenylcarbamate) |
CHIRALPAK IG® and IG-3 | Lux i-Amylose-3 | Amylose tris(3-chloro-5-methylphenylcarbamate) |
CHIRALPAK IC® and IC-3 | Lux i-Cellulose-5 | Cellulose tris(3,5-dichlorophenylcarbamate) |
CHIRALPAK AD®, AD-H®, AD-3, AD-RH®, and AD-3R | Lux Amylose-1 | Amylose tris(3,5-dimethylphenylcarbamate) |
CHIRALPAK AY®, AY-H®, AY-3, AY-RH, and AY-3R | Lux Amylose-2 | Amylose tris(5-chloro-2-methylphenylcarbamate) |
CHIRALCEL® OD®, OD-H®, OD-3, OD-RH®, and OD-3R | Lux Cellulose-1 | Cellulose tris(3,5-dimethylphenylcarbamate) |
CHIRALCEL OZ, OZ-H®, OZ-3, OZ-RH, and OZ-3R | Lux Cellulose-2 | Cellulose tris(3-chloro-4-methylphenylcarbamate) |
CHIRALCEL OJ®, OJ-H®, OJ-3, OJ-RH®, and OJ-3R | Lux Cellulose-3 | Cellulose tris(4-methylbenzoate) |
CHIRALCEL OX-H, OX-3, OX-RH, and OX-3R | Lux Cellulose-4 | Cellulose tris(3-chloro-4-methylphenylcarbamate) |