The immobilization and bonding technology used within the Lux i-Amylose-1 promotes column stability in strong organic solvents, which affords you the ability to expand your chiral separation success with more solvent systems and separation modes.
Separation Mode Chiral |
Phase Composition Regenerated Cellulose (RC) |
Recommended Use Separation of enantiomers and racemic mixtures by reversed phase, normal phase, polar organic and SFC with a fully porous particle, immobilized with a polysaccharide stationary phase. This Immobilization provides additional strong organic solvent ruggedness so that DCM, DMSO and other related strong solvents can be used on column. |
Column:
Lux 5 µm i-Amylose-1 |
Dimension:
250 x 4.6 mm |
Part No.:
00G-4762-E0 |
Mobile Phase:
0.1 % DEA in Hexane / 0.1 % DEA in IPA (90:10) |
Flow Rate:
1 mL/min |
Temperature:
22 ˚C |
Detection:
UV @ 260 nm |
Sample:
Mianserin |
Column Exposed to:
1. MtBE2. Dichloromethane 3. Ethyl Acetate 4. THF 5. Hexane 6. Methanol 7. Ethanol 8. Isopropanol |
Column:
Lux 5 µm i-Amylose-1 |
Dimension:
250 x 4.6 mm |
Part No.:
00G-4762-E0 |
Mobile Phase:
0.1 % DEA in Hexane / 0.1 % DEA in IPA (90:10) |
Flow Rate:
1 mL/min |
Temperature:
Ambient |
Detection:
UV @ 260 nm |
Sample:
Mianserin |
Dimension:
250 x 4.6 mm |
Mobile Phase:
0.1 % DEA in Hexane / 0.1 % DEA in IPA (90:10) |
Flow Rate:
1 mL/min |
Temperature:
Ambient |
Detection:
UV @ 270 nm |
Sample:
Tramadol |
Dimension:
250 x 4.6 mm |
Mobile Phase:
0.1 % DEA in Hexane / 0.1 % DEA in IPA (85:15) |
Flow Rate:
1 mL/min |
Temperature:
Ambient |
Detection:
UV @ 230 nm |
Sample:
Nadolol |
Dimension:
250 x 4.6 mm |
Part No.:
00G-4762-E0 |
Mobile Phase:
0.1 % DEA in Hexane / 0.1 % DEA in IPA (90:10) |
Flow Rate:
1 mL/min |
Temperature:
Ambient |
Detection:
UV @ 260 nm |
Dimension:
250 x 4.6 mm |
Part No.:
00G-4762-E0 |
Mobile Phase:
0.1 % DEA in Hexane / 0.1 % DEA in Ethyl Acetate (60:40) |
Flow Rate:
1 mL/min |
Temperature:
Ambient |
Detection:
UV @ 220 nm |
Dimension:
250 x 4.6 mm |
Part No.:
00G-4762-E0 |
Mobile Phase:
0.1 % TFA in Hexane / 0.1 % TFA in IPA (90:10) |
Flow Rate:
1 mL/min |
Temperature:
Ambient |
Detection:
UV @ 254 nm |
Dimension:
250 x 4.6 mm |
Part No.:
00G-4762-E0 |
Mobile Phase:
Methanol |
Flow Rate:
1 mL/min |
Temperature:
Ambient |
Detection:
UV @ 230 nm |
Dimension:
250 x 4.6 mm |
Part No.:
00G-4762-E0 |
Mobile Phase:
0.1 % TFA in Hexane / 0.1 % TFA in Dichloromethane (65:35) |
Flow Rate:
1 mL/min |
Temperature:
Ambient |
Detection:
UV @ 254 nm |
Dimension:
250 x 4.6 mm |
Part No.:
00G-4762-E0 |
Mobile Phase:
0.1 % TFA in Hexane / 0.1 % TFA in THF (70:30) |
Flow Rate:
1 mL/min |
Temperature:
Ambient |
Detection:
UV @ 254 nm |
If you are using one of the DAICEL columns below: | Guaranteed alternative: |
Phase description: |
---|---|---|
CHIRALPAK® IA® | Lux i-Amylose-1 | Amylose tris(3,5-dimethylphenylcarbamate) |
CHIRALPAK IG® and IG-3 | Lux i-Amylose-3 | Amylose tris(3-chloro-5-methylphenylcarbamate) |
CHIRALPAK IC® and IC-3 | Lux i-Cellulose-5 | Cellulose tris(3,5-dichlorophenylcarbamate) |
CHIRALPAK AD®, AD-H®, AD-3, AD-RH®, and AD-3R | Lux Amylose-1 | Amylose tris(3,5-dimethylphenylcarbamate) |
CHIRALPAK AY®, AY-H®, AY-3, AY-RH, and AY-3R | Lux Amylose-2 | Amylose tris(5-chloro-2-methylphenylcarbamate) |
CHIRALCEL® OD®, OD-H®, OD-3, OD-RH®, and OD-3R | Lux Cellulose-1 | Cellulose tris(3,5-dimethylphenylcarbamate) |
CHIRALCEL OZ, OZ-H®, OZ-3, OZ-RH, and OZ-3R | Lux Cellulose-2 | Cellulose tris(3-chloro-4-methylphenylcarbamate) |
CHIRALCEL OJ®, OJ-H®, OJ-3, OJ-RH®, and OJ-3R | Lux Cellulose-3 | Cellulose tris(4-methylbenzoate) |
CHIRALCEL OX-H, OX-3, OX-RH, and OX-3R | Lux Cellulose-4 | Cellulose tris(3-chloro-4-methylphenylcarbamate) |