FOR SECURITY PURPOSES - because Internet Explorer is no longer supported by Microsoft, we suggest that you interact with our secure site through one of our supported browsers - Google Chrome, Firefox, or MS Edge. If you continue to use this website with Internet Explorer you do so at your own risk and you may encounter problems.
Applications
Amino Acids
1312
Separation Mode: Reversed Phase
Reversed Phase
C18(2)
HPLC
Antidepressive Agents, Second-Generation
Biochemical - NOT Polymeric (incl. oligomers)
Biochemical Compound / Nutrient

Amino Acids

Analytes
15-Hydroxytryptophan
2Kynurenine
3Tryptophan
4N-Methyltryptophan
Details
LC Conditions (App ID: 1312)
Column:
Brand Name:
Luna
Part No:
Phase Name:
C18(2)
Sample Note:
Description of Sample Prep and HPLC: Do not use pipette tips or microcentrifuge tubes that have been autoclaved. The water that may collect from the steam and then dry may contaminate the samples. Collection: - Collect sample (3.5-4 ml unheparizied hematocrit tubes of peripheral blood or minimum of 100 mL culture media) - Centrifuge @ 3000 rpm, 4°C, 10 min - Transfer 75mL* of serum or culture media to a new microcentrifuge tube - Sample can now be stored @ -20 °C until ready to perform extraction Extraction: - Add 1.4 mL (2 x 0.7 mL) HPLC-grade methanol, vortex - Spin @ 15,800 g, 0 °C, 15 min - Transfer 1.2mL (2 x 0.6 mL) of supernatant to a new microcentrifuge tube - Dry completely in Speedvac on low heat (2-3 hr) - Store @ -20 °C until ready to run HPLC or proceed directly to next step HPLC: - Warm samples to room temp; resuspend dry extract in 100 mL distilled-deionized water (ddH2O), let sit at RT for about 30 min then vortex - Transfer 95 mL to HPLC sample vials (we use inserts inside vials); no bubbles - HPLC - run on a Luna C18(2) column (Phenomenex, 250mm x 4.6 mm) - 20mL injection volume with a linear water:acetonitrile gradient from 100:0 to 20:80 over 20 min; 1 mL/min - absorbance is read at 225 nm and integrated peaks are calculated by computer - Beckman System Gold 166 detector Standards: 75mL* of each triple standard is extracted as above. Each standard is run in duplicate with the average AUC used to construct a standard curve. Use distilled-deionized water (ddH2O) to make up standards. - Prepare standard stock solutions of kynuerinine, L-tryptophan and 1-methyl-DL-tryptophan (each = 1mg/ml). Protect from light and store @ -70 °C. - Triple standard is a mix of 50ml each of kynuerinine, L-tryptophan and 1-methyl-DL-tryptophan. When brought to a volume of 1ml, the concentration of each = 50 mg/mL - this dilution is used as the most concentrated standard - From the above dilution, make 4 additional serial dilutions (25, 12.5, 6.25 and 1.25 mg/mL) *A 150 mL sample will give a much more readable result if you suspect low amounts of kynuerinine. Directions for dissolving 1-methyl-DL-tryptophan (1 mg/mlL ~4.6mM) total volume 100mL 1-MeTrp 100mg 1N NaOH 1mL distilled H2O 98ml HCl ~1mL Weigh 1-MeTrp and place in bottle. Add 1N NaOH and mix until majority of powder is dissolved. Add water and stir for ~ 1hr. Titrate to pH=7 using 1N HCl. Aliquot and wrap in foil and store @ -70°C.
Similar Applications
search
No Data