FOR SECURITY PURPOSES - because Internet Explorer is no longer supported by Microsoft, we suggest that you interact with our secure site through one of our supported browsers - Google Chrome, Firefox, or MS Edge. If you continue to use this website with Internet Explorer you do so at your own risk and you may encounter problems.
Applications
Artifical sweeteners in Mio Energy using Luna Omega 1.6u Polar C18 50x2.1mm
23856
Separation Mode: Reversed Phase
Reversed Phase
Polar C18
HPLC
Sweetening Agents
Food & Beverage
Food and Beverage (incl. additives
contaminants)
Product / Trade Good

Applications

Artifical sweeteners in Mio Energy using Luna Omega 1.6u Polar C18 50x2.1mm
Analytes
1Acesulfame K
2Sucralose

Analyte not found

Details
LC Conditions (App ID: 23856)
Column:
Brand Name:
Part No:
Phase Name:
Polar C18
Elution Type:
Gradient
Mobile Phase:
A: 0.1 Formic Acid in Water
B: 0.1% Formic Acid in Acetonitrile
Gradient Profile:
Step No.Time(min)%A%B
10973
240100
34.1973
47973
Flow Rate:
0.4 mL/min
Temperature:
22°C
Detection:
Tandem Mass Spec (MS-MS) (22°C)
Detector Info:
SCIEX API 4000™