For security purposes
FOR SECURITY PURPOSES - because Internet Explorer is no longer supported by Microsoft, we suggest that you interact with our secure site through one of our supported browsers - Google Chrome, Firefox, or MS Edge. If you continue to use this website with Internet Explorer you do so at your own risk and you may encounter problems.
Applications
Gabapentin extracted from plasma (25 µg/mL) using PPT on a Kinetex C18 2.6µm, 50x2.1mm
19689
Separation Mode: Reversed Phase
Reversed Phase
C18
HPLC
Antiparkinson Agents
Clinical

Applications

Gabapentin extracted from plasma (25 µg/mL) using PPT on a Kinetex C18 2.6µm, 50x2.1mm
Analytes
1Gabapentin-d4
2Gabapentin
Compound Name
Gabapentin
CID
3446
Molecular Formula
C9H17NO2
Molecular Weight
171
No. Hydrogen Bond Acceptors
3
No. Hydrogen Bond Donors
2
Details
LC Conditions (App ID: 19689)
Column:
Brand Name:
Kinetex
Part No:
Phase Name:
C18
Elution Type:
Gradient
Mobile Phase:
A: 5 mM Ammonium formate
B: Acetonitrile
Gradient Profile:
Step No.Time(min)%A%B
10973
21973
331090
Flow Rate:
0.4 mL/min
Temperature:
0°C
Detection:
Mass Spectrometer (MS) (22°C)
Detector Info:
SCIEX API 3000™