For security purposes
FOR SECURITY PURPOSES - because Internet Explorer is no longer supported by Microsoft, we suggest that you interact with our secure site through one of our supported browsers - Google Chrome, Firefox, or MS Edge. If you continue to use this website with Internet Explorer you do so at your own risk and you may encounter problems.
Applications
Axia Packed Gemini-NX 5 µm C18 (high pH loading - Lidocaine and Diphenhydramine - 110mg/100µL)
17712
Separation Mode: Reversed Phase
Reversed Phase
NX-C18
HPLC
Antipruritics
Pharmaceutical
Therapeutic / Clinical

Applications

Axia Packed Gemini-NX 5 µm C18 (high pH loading - Lidocaine and Diphenhydramine - 110mg/100µL)
Analytes
1Lidocaine
2Diphenhydramine
Compound Name
Lidocaine
CID
3676
Molecular Formula
C14H22N2O
Molecular Weight
234
No. Hydrogen Bond Acceptors
2
No. Hydrogen Bond Donors
1
Details
LC Conditions (App ID: 17712)
Column:
Brand Name:
Part No:
Phase Name:
NX-C18
Elution Type:
Gradient
Mobile Phase:
A: 0.2 % NH4OH in Water
B: Acetonitrile
Gradient Profile:
Step No.Time(min)%A%B
10955
25595
Flow Rate:
30 mL/min
Temperature:
22°C
Detection:
UV-Vis Abs.-Variable Wave.(UV) @ 254 nm (22°C)
Sample Note:
SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard PREP Cartridge, Gemini-NX C18 15 x 21.2mm, Ea Part No.: AJ0-8370 - Holder Part No.: AJ0-8223

Order Items Used in This Application

Similar Applications
search
No Data