FOR SECURITY PURPOSES - because Internet Explorer is no longer supported by Microsoft, we suggest that you interact with our secure site through one of our supported browsers - Google Chrome, Firefox, or MS Edge. If you continue to use this website with Internet Explorer you do so at your own risk and you may encounter problems.
Applications
EPA Method 642, Biphenyl and o-Phenylphenol
14490
Separation Mode: Reversed Phase
Reversed Phase
EPA 642
C18(2)
HPLC
Anti-Infective Agents
Environmental
Pollutant / Contaminant
Environmental / Health

Applications

EPA Method 642, Biphenyl and o-Phenylphenol
Analytes
1Biphenyl
2o-Phenylphenol
Compound Name
Biphenyl
CID
7095
Molecular Formula
C12H10
Molecular Weight
154
Details
Official Method: EPA 642
LC Conditions (App ID: 14490)
Column:
Brand Name:
Part No:
Phase Name:
C18(2)
Elution Type:
Gradient
Mobile Phase:
A: Water
B: Acetonitrile
Gradient Profile:
Step No.Time(min)%A%B
102080
2100100
Flow Rate:
1.5 mL/min
Temperature:
22°C
Detection:
UV-Vis Abs.-Variable Wave.(UV) @ 254 nm (22°C)
Sample Note:
SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, C18 4 x 3.0mm, 10/Pk Part No.: AJ0-4287 - Holder Part No.: KJ0-4282